Math in the Workplace - Algebra
MICRON TECHNOLOGY, INC.,
Semiconductor Manufacturing
| |
Job Description: Analyzes chemicals, tools, and wafers for the fabrication process. Analyzes waste products resulting from the memory chip fabrication process. |
| |
|

Problem:
The government requires that companies analyze and report the amount of ethyl lactate present in waste sent to a waste disposal company.
The ethyl lactate sample area is 6,821,193 counts. An ethyl lactate standard has a "concentration" of 10.16 wt% and a peak area of 10,617,862 counts.
What is the concentration (amount) of ethyl lactate in a solvent sample from gas chromatography data?

MICRON TECHNOLOGY, INC.
|

Solution:
Since the relationship is linear, use a ratio:
Concentrate of standard (X1) is to counts of standard (c1) as concentrate of sample (X2) is to counts of sample (c2)
X2 wt % = 10.16 wt % |
10,617,862

6,821,193 |
 |
| = 1.556 x 10.16 wt % |
= 15.81 wt % |
Concentration of sample= 15.81 wt %